5. IVC, VENOUS CONGESTION & FLUID RESPONSIVENESS
5.1 IVC
Spontaneous breathing
IVC <1.5 cm with collapse >50%: collapsed or small; low CVP; possible hypovolaemia. [1]
IVC 1.5–2.5 cm with collapse 20–50%: normal or intermediate; indeterminate; correlate clinically. [1]
IVC >2.1 cm with collapse <50%: formal elevated RAP estimate; standard formal echo RAP ≈15–20 mmHg. [1]
IVC >2.5 cm with collapse <50%: plethoric or marked POCUS finding; avoid empiric fluids. [1]
IVC >2.5 cm with collapse <20%: clearly plethoric; high suspicion of volume overload or impaired RV filling. [1]
IVC >3.0 cm with minimal collapse: markedly plethoric; late warning; possible iatrogenic congestion. [1]
IVC >3.5 cm: marked plethora in some protocols; not a universal formal RAP cutoff. [1]
Collapsibility index, spontaneous breathing: Formula: (Dmax − Dmin)/Dmax × 100. [1]
50%: low CVP. 20–50%: indeterminate. <20%: high CVP. [1] For fluid responsiveness, a collapsibility threshold of ≈40–41% or greater suggests fluid responsiveness. [1,2] Reported specificity ≈80–97%. [1,2] High collapsibility increases the likelihood of responsiveness but does not guarantee it; low collapsibility reduces the likelihood but does not absolutely exclude it. [1]
Technique for spontaneous breathing: Measure during quiet spontaneous tidal breathing. Dmax at end-expiration; Dmin during inspiration. If a quiet tidal inspiration does not elicit a clear Dmin, a brief controlled sniff may be used. Do not use sustained maximal inspiratory strain or Valsalva-like effort. In fully mechanically ventilated patients without spontaneous breathing activity, IVC collapsibility is not the appropriate index; use IVC distensibility or mean-based variability instead. [1]
Integration with diameter Fluid responsiveness is more likely when the IVC is relatively small, commonly <2.1 cm, with collapse >50%, suggesting lower RAP. Fluid unresponsiveness is more likely when the IVC is relatively plethoric, commonly >2.1 cm, with collapse <50%. Very low collapsibility, <10–12%, is particularly indicative of fluid unresponsiveness. Published thresholds for spontaneous-breathing IVC variability are not uniform and have ranged ≈8–50% depending on population, ventilatory conditions, and technique. Diagnostic accuracy in spontaneously breathing patients is less robust than in fully ventilated patients; integrate with other dynamic and static haemodynamic assessments. [1,2]
Mechanical ventilation
Do not use inspiratory collapse for RAP. [1]
IVC distensibility, Dmin-based: (Dmax − Dmin)/Dmin × 100. [1]
Common general controlled-ventilation threshold: 15% or greater. [1] Validation-specific range: ≈12–21%. [1] An 18% threshold remains appropriate in selected fully ventilated septic shock protocols; it is a validation-specific operating point, not the only standard. [1,2]
Validity: tidal volume ≥8 mL/kg, stable ventilator settings, no spontaneous effort. [1]
Invalidity: high PEEP, low tidal volume, spontaneous effort, RV dysfunction, intra-abdominal hypertension. [1]
IVC variability, mean-based: (Dmax − Dmin)/[(Dmax + Dmin)/2] × 100.
Common threshold: 12%. [1] Same validity/invalidity conditions as Dmin-based distensibility. [1] A 15% value labelled “distensibility” refers to the Dmin formula and is a common operational threshold. Do not interchange 15% Dmin-based distensibility, 18% septic-shock-specific distensibility, and 12% mean-based variability. [1,2]
Formula warning: Collapsibility index, Dmin-based distensibility index, and mean-based variability are not interchangeable. State which formula was used. Do not mix thresholds from different formulas. [1,2]
Pitfall:
Using IVC collapsibility in mechanical ventilation without caution.
5.2 VExUS — Venous Excess Ultrasound
VExUS integrates four bedside ultrasound sites. Each site is scored 0 or 1. [3]
Sites
IVC: normal diameter with expected respiratory variation vs plethoric/dilated IVC with reduced respiratory variation. [3]
Hepatic vein: systolic predominance vs S/D <1, diastolic attenuation or reversal, or atrial reversal. [3]
Portal vein: continuous antegrade flow vs increased pulsatility, attenuated or reversed diastolic flow. Abnormal portal pulsatility is commonly defined as pulsatility fraction >50%. [3]
Intrarenal vein: continuous antegrade diastolic flow vs loss, attenuation, or reversal of diastolic flow. [3] Exact portal and intrarenal Doppler thresholds can vary by protocol; state institutional algorithm.
Conventional VExUS grading
Grade 0: IVC normal and all venous Doppler normal. No systemic venous congestion. [3]
Grade 1: isolated IVC abnormality; hepatic, portal, and intrarenal Doppler normal. At risk for venous congestion. [3]
Grade 2: exactly one venous Doppler abnormality. IVC may be normal or abnormal. Possible congestion. [3]
Grade 3: two or more venous Doppler abnormalities. IVC may be normal or abnormal. Probable congestion. [3]
Examples
Plethoric IVC only: VExUS 1.
Normal IVC + abnormal hepatic vein only: VExUS 2.
Abnormal IVC + abnormal hepatic vein only: VExUS 2 (only one venous Doppler site abnormal).
Abnormal hepatic vein + abnormal intrarenal vein: VExUS 3.
All four sites abnormal: VExUS 3. [3]
If an institution uses an additive 0–4 point system, state this explicitly; it is not identical to conventional categorical VExUS grading.
Interpretive caveats
VExUS is a likelihood scale, not a linear severity scale. [3] Grade 2 should be interpreted cautiously as possible congestion with higher false-positive susceptibility; a single venous Doppler abnormality may be influenced by non-congestive factors.
Grade 2 is not equivalent to Grade 3. [3]
VExUS is not a simple volume-status score. It reflects the interaction of venous return and cardiac function. [3] The same VExUS grade can arise from elevated RAP, RV failure, elevated PVR, LV filling-pressure elevation, high intra-abdominal pressure, pericardial constraint, mechanical ventilation, arrhythmia, or altered venous capacitance. [3,4]
Important confounders: spontaneous vs mechanical ventilation, PEEP and tidal volume, atrial fibrillation/other arrhythmias, significant tricuspid regurgitation, RV systolic/diastolic dysfunction, LV diastolic dysfunction, pericardial effusion/tamponade, elevated intra-abdominal pressure, hepatic/renal parenchymal disease, probe positioning, respiratory timing. [3,4]
In sepsis and mixed ICU populations, VExUS–outcome associations are less consistent than in some cardiac surgery cohorts. [3]
Lung ultrasound score and VExUS answer different questions; discordant patterns are clinically meaningful. [3] (see S4.1)
5.3 Fluid responsiveness — dynamic indices
IVC collapsibility
Patient state: spontaneous breathing.
Key threshold: ≈40–41% or greater. Reported specificity: ≈80–97%.
Validity: quiet respiration, good window. Invalidity: PEEP, arrhythmia, RV failure, pericardial disease. [1,2]
IVC distensibility, Dmin-based
Patient state: controlled mechanical ventilation, no spontaneous effort.
Key threshold: commonly 15% or greater; validation-specific range 12–21%; 18% in selected septic shock protocols.
Validity: tidal volume ≥8 mL/kg, stable settings, no spontaneous effort. Invalidity: high PEEP, low tidal volume, spontaneous effort, RV dysfunction, intra-abdominal hypertension. [1,2]
LVOT VTI or peak aortic velocity respiratory variation
Patient state: controlled mechanical ventilation.
Key statistic: sensitivity ≈79% reported in mechanical ventilation circulatory failure.
Validity: no arrhythmia, stable haemodynamics. Invalidity: atrial fibrillation, spontaneous breathing, poor compliance, low tidal volume, RV failure. [5]
Passive leg raising with LVOT VTI or stroke volume
Any patient state, especially when IVC assumptions are not met.
Positive response: 10–15% or greater increase in stroke volume, cardiac output, or LVOT VTI. A 10–15% response is associated with excellent predictive performance.
Validity: supine position, legs raised ≈45°, maintained 30–60 s. Invalidity/caution: lower limb fracture, DVT, pelvic or hip injury, severe oedema. [1,2]
SVC collapsibility
TEE-based, not standard POCUS.
Threshold: >39% in septic shock; specificity ≈84% in mechanical ventilation circulatory failure.
Validity: TEE available. Limitation: limited TTE access. [5]
Formula warning
Percent variation = 100 × (max − min)/[(max + min)/2].
Distensibility index = 100 × (Dmax − Dmin)/Dmin.
Collapsibility index = 100 × (Dmax − Dmin)/Dmax.
These are not interchangeable. State the formula. Do not apply a threshold from one formula to a value calculated with another. [1,2]
5.4 Multimodal low-output/hypovolaemia pattern — sepsis
Aortic VTI <16 cm plus mitral E <67 cm/s plus SVC collapsibility >39% is highly suggestive of hypovolaemia or fluid responsiveness in septic shock. [5]
5.5 Fluid tolerance — harm-limiting markers
New or increasing B-lines: developing interstitial oedema; reduced fluid tolerance. (see S4.1) VExUS grade 2–3: systemic venous congestion; limited capacity for further volume. [3] IVC >2.5 cm plus poor collapse: plethoric; avoid empiric fluids. [1] E/A shift from <1 to >2 during resuscitation: approaching preload ceiling; further fluid of limited benefit. (see S3.5.1) Replacement of A-lines by B-lines is a practical bedside stop signal for further fluid unless the clinical question changes. (see S4.1) Responsiveness is not tolerance. A patient may be fluid responsive and have limited fluid tolerance. [2,3]
5.6 Passive leg raising — practical points
Reversible autotransfusion ≈300 mL. [1,2] Positive response: 10–15% or greater increase in stroke volume or LVOT VTI. [1,2] The response is transient; interpret in context. Cautions: lower limb DVT, hip or pelvic fracture, severe oedema, intra-abdominal hypertension. [6] PLR is a preload test, not a fluid bolus. [1]
5.7 Pitfalls
Using IVC collapsibility in mechanical ventilation without caution.
IVC diameter is a number, not a diagnosis.
Collapsibility index is less reliable in mechanical ventilation.
Plethoric IVC in heart failure is expected; in a young patient with sudden dyspnoea and leg swelling, consider PE.
Collapsible IVC in sepsis does not guarantee fluid responsiveness.
VExUS grade 2 is possible congestion, not definitively severe congestion.
VExUS reflects venous return plus cardiac interaction, not simple fluid overload.
VExUS is affected by COPD, PEEP, mechanical ventilation, obesity, tamponade, and CVC.
Formula-specific thresholds: do not mix.
IVC greater than 2.1 cm with collapse less than 50% is the formal elevated-RAP criterion.
IVC greater than 3.5 cm is not a universal formal RAP cutoff.
Using 18% as the only standard Dmin-based distensibility cutoff; the common general threshold is 15%, with 18% as a septic-shock-specific operating point.
Interchanging Dmin-based distensibility with mean-based variability.
Applying Valsalva-like effort for IVC collapsibility measurement.
Using a linear probe as the standard transducer for adult subcostal IVC assessment.
Ignoring PEEP, spontaneous effort, low tidal volume, RV failure, intra-abdominal hypertension, and arrhythmia.
References
Monnet X, et al. ESICM guidelines on circulatory shock and hemodynamic monitoring: 2025 update. Intensive Care Med. 2025;51(11):1971-2012. doi:10.1007/s00134-025-08137-z.
Huard K, Deschamps J, Couture EJ, et al. Venous congestion in critical care: combining VExUS, lung ultrasound, and echocardiography. Ann Intensive Car. 2026;16:100127. doi:10.1016/j.aicoj.2026.100127.
Malbrain MLNG, et al. Fluid management in sepsis. In: Malbrain MLNG, Wong A, Nasa P, Ghosh S, eds. Rational Use of Intravenous Fluids in Critically Ill Patients. Cham: Springer; 2024. doi:10.1007/978-3-031-42205-8.
Mekontso Dessap A, AlShamsi F, Belletti A, et al. European Society of Intensive Care Medicine (ESICM) 2025 clinical practice guideline on fluid therapy in adult critically ill patients: part 2 — the volume of resuscitation fluids. Intensive Care Med. 2025;51(3):461-477. doi:10.1007/s00134-025-07840-1.
Chen L, Hong L, Ma A, et al. Intraoperative venous congestion rather than hypotension is associated with acute adverse kidney events after cardiac surgery: a retrospective cohort study. Br J Anaesth. 2022;128(5):785-795. doi:10.1016/j.bja.2022.01.032.
Beurton A, Teboul JL, Girotto V, et al. Intra-abdominal hypertension is responsible for false negatives to the passive leg raising test. Crit Care Med. 2019;47:e639-e647.